MATLAB SIMPOWERSYSTEMS 5 Uživatelský manuál Strana 16

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 20
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 15
Palestine Polytechnic University
Workshop Matlab/Simulink in Drives and Power electronics Lecture 418-21 May 2009
/ 20
Tunning the snubbers
If firing pulses to forced-commutated devices are blocked, only antiparallel
diodes operate, and the bridge operates as a diode rectifier. In this condition
appropriate values of Rs and Cs must also be used.
When the system is discretized, use the following formulas to compute
approximate values of Rs and Cs,
where
These Rs and Cs values are derived from the following two criteria:
The snubber leakage current at fundamental frequency is less than 0.1% of nominal
current when power electronic devices are not conducting.
The RC time constant of snubbers is higher than two times the sample time Ts.
These Rs and Cs values that guarantee numerical stability of the discretized
bridge can be different from values of a physical circuit.