Using the RTDX Control to Change the Load at Run Time
6-8
7) Right-click on the Statistics View area and choose Property Page from
the pop-up menu. Highlight the items shown here.
8) Click OK.
9) Resize the Statistics area to see the fields for the statistics you selected.
10) Right-click on the RTA Control Panel and choose Property Page from the
pop-up menu.
11) Set the Refresh Rate for Message Log/Execution Graph to 1 second and
the Refresh Rate for Statistics View/CPU Load Graph to 0.5 seconds.
Then click OK.
12) Choose Tools
RTDX.
13) Notice that RTDX is already enabled. This happened behind-the-scenes
in Step 2 when you opened a DSP/BIOS control. DSP/BIOS controls
configure and enable RTDX in continuous mode. In continuous mode,
RTDX does not record data received from the target in a log file (as it
does in non-continuous mode). This allows continuous data flow. (If your
program does not use DSP/BIOS, you can use the RTDX area to
configure and enable RTDX directly.)